Thread Tools |
|
|
#1 |
|
DriverHeaven Junior Member
Join Date: Aug 2008
Posts: 20
Rep Power: 0 ![]() |
3549: DSP Prolog Labels No Longer Meaningfully Describe Connectors
In the process to troubleshooting other issues, I installed the new 3549 Drivers last night.
I just noticed that hovering over the connectors of the Prolog in DSP, the pop-up descriptions now generically indicate "in0, in1, in2, in3, in4..." etc. (on v3545) They used to indicate "Line-in1 L, Line-in1 R, CoAx-in L, CoAx-in R..." Can anyone else confirm? Note: This is with WinXP/SP3 on an Audigy2 ZS PlatinumPro I also tried resetting global settings, and reinstalling kX (in case something went awry from troubleshooting my original issues), and the DSP display remains the same. |
|
|
|
|
|
#2 |
|
HardwareHeaven Extreme Member
Join Date: Jan 2005
Posts: 5,507
Rep Power: 61 ![]() ![]() ![]() ![]() ![]() ![]() |
Re: 3549: DSP Prolog Labels No Longer Meaningfully Describe Connectors
Yes, this is the same issue that I reported (with 3548) here: 3548 bug reports - X86 ONLY (post #24)
|
|
|
|
|
|
|
|
DriverHeaven Junior Member
Join Date: Aug 2008
Posts: 20
Rep Power: 0 ![]() |
Re: 3549: DSP Prolog Labels No Longer Meaningfully Describe Connectors
OK well then... Consider it also confirmed in 3549 on x86, I guess.
|
|
|
|
|
|
#4 |
|
HardwareHeaven Extreme Member
Join Date: Jan 2005
Posts: 5,507
Rep Power: 61 ![]() ![]() ![]() ![]() ![]() ![]() |
Re: 3549: DSP Prolog Labels No Longer Meaningfully Describe Connectors
Did the tooltips seem less responsive to you too?
e.g. When I am looking for a particular I/O, I will drag the mouse down across each pin looking for that descriptive text, and now (aside from the missing descriptions), it seems much less responsive then it used to be. |
|
|
|
|
|
#5 | |
|
DH Senior Member
Join Date: Jan 2003
Location: The Netherlands
Posts: 1,930
Rep Power: 62 ![]() ![]() ![]() ![]() |
Re: 3549: DSP Prolog Labels No Longer Meaningfully Describe Connectors
Quote:
|
|
|
|
|
|
|
#6 |
|
HardwareHeaven Extreme Member
Join Date: Jan 2005
Posts: 5,507
Rep Power: 61 ![]() ![]() ![]() ![]() ![]() ![]() |
Re: 3549: DSP Prolog Labels No Longer Meaningfully Describe Connectors
I am not sure, it is hard to say... It seems as though the plugin tooltip gets stuck at times (when it is already showing), as I am moving the mouse across a plugin.
i.e. Sometimes the tooltip will smoothly follow the mouse, and at other times it moves in studder steps. When it is in a stuck state, movement over a pin is missed (i.e. the pin's tooltip is not shown), etc. Last edited by Russ; Sep 1, 2009 at 01:12 AM. |
|
|
|
|
|
#7 |
|
kX Project Lead Programmer and Coordinator
Join Date: Dec 2002
Posts: 3,106
Rep Power: 73 ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Ответ: 3549: DSP Prolog Labels No Longer Meaningfully Describe Connectors
labels should be fixed in 3540
thanks! ![]() E. |
|
|
|
|
|
#8 |
|
HardwareHeaven Extreme Member
Join Date: Jan 2005
Posts: 5,507
Rep Power: 61 ![]() ![]() ![]() ![]() ![]() ![]() |
Re: 3549: DSP Prolog Labels No Longer Meaningfully Describe Connectors
Both issues appear to be fixed in 3550.
Thanks |
|
|
|
![]() |
| Bookmarks |
| Thread Tools | |
|
|