Xigmatek NRP-PC602 600W PSU - Introduction
There are many power supply products available to the budget-minded enthusiasts in today’s marketplace. Every power supply manufacturer has at least one series of units combining performance and good value, each with its distinct set of features and performance. Today we are going to have a look at a new PSU from Xigmatek which is designed with high electrical efficiency and a value orientated price in mind. It has to compete against many similar products from several manufacturers so will really have to excel in one area to stand out. |
Manufacturer Features & Specifications
- High efficiency over 85% - Higher efficiency, lower energy loss, cooler our Earth.
- Compliant with ATX12V Ver.2.3 - Compliant with latest Intel ATX12V Ver.2.3 PSU design guide.
- 0.99 Active PFC rate - The highest AC utility rate and active switch for universal AC voltage.
- Real and stable 600W output - Continuous 600W total DC output for real 100% loading.
- DC quality with low ripple noise - Low ripple noise DC output for better devices performance.
- Japanese 105°C Main Capacitor - High-end and more stable Japanese capacitor for better output performance.
- 140mm silent cooling fan - The bigger fan is equal to lower RPM and less noise.
- Smart thermal fan control - Fan RPM was controlled by temperature and keep silence in typical loading.
- All DC cables with mesh sleeve - Reduce airflow resistance for better thermal release in PC case.
- PCIe graphic card connector support - Support high-end graphic card with PCIe 6/8pin connector.
| Product Name |
NRP-PC602 |
| Product Number |
CPH-0600U-X02 |
| Power |
600W |
| Dimension |
150mm(L) x 160mm(W) x 86mm(H) |
| Power Factor |
PF > 0.9 |
| Cooling System |
14cm fan, Max. 1800RPM±10% |
| Hold-up Time |
16ms |
| Noise Level |
16dBA ±10% at 800RPM |
| INPUT |
| Input Voltage |
100-240VAC |
| Input Frequency Range |
47/63Hz |
| MTBF |
100,000 hrs minimum (at 25°C) |
| Input Current |
115Vac/10A max. 230Vac/5A max. |
| OUTPUT |
| |
Max/Min |
Regulation |
Ripple & Noise |
Output |
| +5V |
15.0A/0.2A |
+5, -5% |
50mV |
130W |
| +3.3V |
24.0A/0.5A |
+5, -5% |
50mV |
| +12V1 |
30.0A/0.5A |
+5, -5% |
120mV |
504W |
| +12V2 |
22.0A/1.0A |
+5, -5% |
120mV |
| -12V |
0.3A/0.0A |
+10, -10% |
120mV |
3.6W |
| +5Vsb |
2.5A/0.1A |
+5, -5% |
50mV |
12.5W |
| Total Power |
600W |
| Environment |
| Operating Temp. |
10°C to 40°C |
| Storage Temp. |
-40°C to 70°C |
| Operating Humidity |
20% to 90%, non-condensing |
| Storage Humidity |
5% to 95%, non-condensing |
| Protection |
| |
DC Rail |
Trigger Point/Range |
| Over Voltage Protection |
Trippunkt +3,3 V |
4.5 V max. |
| Trippunkt +5,0 V |
7.0V max. |
| Trippunkt +12,0 V |
15.6V max. |
| Over Current Protection |
The power supply should provide OCP and should shutdown before 240VA of each output power (included +5V, +3.3V). The power supply should provide OCP when over current output of each output power (included +12V). |
| Short Protection |
All output to GND |
|
|