Sapphire FirePsu 625W

Sapphire FirePsu 625W

Sapphire FirePsu 625W Testing

Sapphire FirePSU 625W PSU, 25% Load
Voltage Line
Power Load (A)
Minimum (V)
Maximum (V)
Delta (V)
3.3V
6
3.401
3.407
0.006
5V
5
5.236
5.241
0.005
12V1
3
12.320
12.322
0.002
12V2
3
12.309
12.312
0.003
12V3
3
12.300
12.307
0.007

Sapphire FirePSU 625W PSU, 50% Load
Voltage Line
Power Load (A)
Minimum (V)
Maximum (V)
Delta (V)
3.3V
12
3.398
3.400
0.002
5V
10
5.231
5.235
0.004
12V1
6
12.318
12.321
0.003
12V2
6
12.301
12.305
0.004
12V3
6
12.298
12.305
0.007

Sapphire FirePSU 625W PSU, 75% Load
Voltage Line
Power Load (A)
Minimum (V)
Maximum (V)
Delta (V)
3.3V
12
3.385
3.396
0.011
5V
10
5.228
5.234
0.006
12V1
11
12.311
12.320
0.009
12V2
11
12.298
12.304
0.006
12V3
10
12.288
12.297
0.009

Sapphire FirePSU 625W PSU, 100% Load
Voltage Line
Power Load (A)
Minimum (V)
Maximum (V)
Delta (V)
3.3V
18
3.380
3.391
0.011
5V
15
5.219
5.228
0.009
12V1
14
12.307
12.317
0.010
12V2
13
12.295
12.303
0.008
12V3
13
12.279
12.291
0.012

 

Sapphire FirePSU 625W PSU, 30-100% load voltage regulation test

3.3V
5V

12V1
12V2

12V3

Sapphire FirePSU 625W PSU, efficiency graph

Power Load
30%
40%
50%
60%
70%
80%
90%
100%
Efficiency
84%
87%
88%
86%
86%
85%
84%
83%

Sapphire FirePSU 625W PSU, thermal performance

Load (%)
25%
50%
75%
100%
Intake temperature (Celsius)
19.9
22.5
27.4
30.0
Exhaust Temperature (Celsius)
23.5
28.1
35.1
42.5
Temperature Delta (Celsius)
3.6
5.6
7.7
12.5

The electrical performance of the FirePSU is simply outstanding. The voltage regulation circuit appears to be highly responsive and keeps the voltage lines very stable under constant load shifts. The efficiency can reach a maximum of 88% at typical load and drops down to a minimum of 83% at maximum load, which is admirable by today’s standards.

As the efficiency of the unit is very high, less power is wasted (as heat) and the fan doesn’t have to spin fast in order to keep the unit within operational temperatures. This makes the FirePSU very cool running and entirely quiet as long as it isn’t heavily loaded. While this product is operating under typical load you wouldn’t be able to notice any noise coming from it, however when the load exceeds 80% of the unit’s maximum output the FirePSU tends to warm up considerably and the fan starts spinning faster, becoming clearly audible.

About Author

Stuart Davidson

It appears you have AdBlocking activated

Unfortunately AdBlockers interfere with the shopping cart process

To continue with the payment process can we ask you to

deactivate your AdBlocking plugin

or to whitelist this site. Then refresh the page

We thank you for your understanding


Hardwareheaven respect you right to employ plugins such as AdBlocker.
We would however ask you to consider whitelisting this site
We do not allow intrusive advertising and all our sponsors supply items
relevant to the content on the site.

Hardwareheaven Webmaster

visited